11 Aug 2020 14:37 - 11 Aug 2020 14:38 #832669 by loudhvx
Replied by loudhvx on topic Won't start
As Mikaw explained, the ignition and kill switches do not short anything to ground on Kz's. A grounding kill switch or ignition switch is for magneto driven ignitions or CDI ignitions which are generally not found on Kz's.

Here's a bunch of different ignition types and their various architectures. It explains why there are so many different types of ignition coils out there.
s3.amazonaws.com/gpzweb/Ignition/Ignitio...esAndCoilWiring.html
Last edit: 11 Aug 2020 14:38 by loudhvx.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 00:53 #832690 by Jackasaurus
Replied by Jackasaurus on topic Won't start

F64 wrote:

Jackasaurus wrote: Okay, I think I've found something! So went to double check static timing and both sides of the points were earthed out, currently chasing it back, positive on the coil seems to be earthen so time to pull apart the wiring and find out what's going on!


Jack,
Did you find 0 volts on the positive side of the coil?
For this to be valid:

Meter on DC V
black probe on negative battery post
red probe on positive coil terminal
Ignition must be on/engine off
All connections connected
Points closed

If this is the case, you have a break in your positve 12v line to the coil positive terminal.
But all of the above has to happen. Ignition must be on like Gavroyer said.


I had close to battery voltage on the terminal and about 1v drop when I plugged it into the coil, so I'm getting power there, I just seem to be also have an earth somewhere? Getting into it though there's some horrible wiring in here various 3 into one bodges etc

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 00:54 - 12 Aug 2020 00:58 #832691 by Jackasaurus
Replied by Jackasaurus on topic Won't start
Apparently still getting a hang of this forum :silly:
Last edit: 12 Aug 2020 00:58 by Jackasaurus.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 07:02 - 12 Aug 2020 07:40 #832702 by F64
Replied by F64 on topic Won't start
when you check voltages you need the system under load as well as everything connected and on.
You will have 0 volts on the negative side of the coil when the points are closed(ignition on/engine off). That 0 volts will go from the negative side of the coil through the points all the way to ground.

When the points are open you will have battery voltage all the way from the battery to the coil side of the points' contacts. The other side of the points' contacts will have 0 volts.

You should hook your meter up to the coil and fire the bike up. You need to look at the circuit when it fails.
meter on DC V
black probe on negative battery post
red meter probe on negative coil terminal
the voltage will bounce between 12v and 0v.
but i want to know what the meter says when the engine dies.
Also, note the position of the points open or closed

81-KZ440-D2.
Louis Dudzik's GM HEI ignitor conversion installed 2015 s3.amazonaws.com/gpzweb/Ignition/GPZgmHEImod.html
Motogadget m-unit blue installed 2017.
LIC, NY
Last edit: 12 Aug 2020 07:40 by F64.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 07:46 #832708 by Mikaw
Replied by Mikaw on topic Won't start
Can I ask a question? With ignition on points open will you get battery voltage thru the coil. Example, If meter black on bat negative meter red on coil primary I know you should have bat voltage. Move red to points side of coil will you still get bat voltage after passing thru primary coil windings

1976 KZ 900 A4 kzrider.com/forum/11-projects/613548-1976-kz-900-a4
1976 KZ 900 B1 LTD
1978 KZ 1000 B2 LTD
1980 KZ 750 E1
Kowledge Speaks, But Wisdom Listens.
Jimi Hendrix.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 08:41 - 12 Aug 2020 08:51 #832714 by F64
Replied by F64 on topic Won't start
yep,
all the way back to where the points open.
what is interesting... you won't have a voltage drop on that line. you will see pretty close to battery voltage.

points being open is just like the 3rd example down.
photo: dan sullivan


81-KZ440-D2.
Louis Dudzik's GM HEI ignitor conversion installed 2015 s3.amazonaws.com/gpzweb/Ignition/GPZgmHEImod.html
Motogadget m-unit blue installed 2017.
LIC, NY
Attachments:
Last edit: 12 Aug 2020 08:51 by F64.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 09:07 #832716 by Mikaw
Replied by Mikaw on topic Won't start
Interesting! Without getting to deep into coil design, and understand the battery + needs a ground - to complete a circuit. Are the primary windings grounded internally?

1976 KZ 900 A4 kzrider.com/forum/11-projects/613548-1976-kz-900-a4
1976 KZ 900 B1 LTD
1978 KZ 1000 B2 LTD
1980 KZ 750 E1
Kowledge Speaks, But Wisdom Listens.
Jimi Hendrix.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 09:12 - 12 Aug 2020 09:19 #832719 by loudhvx
Replied by loudhvx on topic Won't start

Mikaw wrote: Interesting! Without getting to deep into coil design, and understand the battery + needs a ground - to complete a circuit. Are the primary windings grounded internally?


In our case, no. But in other ignition designs, yes. That link I posted shows some which do and don't, but some designs the answer is maybe, and has to be determined experimentally if you really need to know. Most often, it's a CDI or magneto coil that has a primary ground connection.

Usually the bigger mystery is how the secondary connections are wired. That link shows how to figure out the secondary wiring on a mystery coil.
Last edit: 12 Aug 2020 09:19 by loudhvx.
The following user(s) said Thank You: Mikaw

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 09:34 - 12 Aug 2020 09:35 #832720 by Mikaw
Replied by Mikaw on topic Won't start
Last question and I’ll stop highjacking the thread.

This is were electricity gets beyond my capacity and turns into PFM. See read arrow, is there 12v at that point without a completion back to ground, to allow current flow? Take the coil out and replace it with a light bulb, if F64 is correct wouldn’t there be current through the bulb and it would illuminate?


1976 KZ 900 A4 kzrider.com/forum/11-projects/613548-1976-kz-900-a4
1976 KZ 900 B1 LTD
1978 KZ 1000 B2 LTD
1980 KZ 750 E1
Kowledge Speaks, But Wisdom Listens.
Jimi Hendrix.
Attachments:
Last edit: 12 Aug 2020 09:35 by Mikaw.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 09:47 - 12 Aug 2020 10:11 #832721 by F64
Replied by F64 on topic Won't start
there will be 12.5 right up to the break.

a light bulb would not light and the result would be the same. Current will not flow as the circuit is open. 12.5 volts up to the break as before.
This is how you find out where the break in the wire is... on the other side of the break is 0 volts.

81-KZ440-D2.
Louis Dudzik's GM HEI ignitor conversion installed 2015 s3.amazonaws.com/gpzweb/Ignition/GPZgmHEImod.html
Motogadget m-unit blue installed 2017.
LIC, NY
Last edit: 12 Aug 2020 10:11 by F64.

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 12:10 #832732 by Jackasaurus
Replied by Jackasaurus on topic Won't start

F64 wrote: when you check voltages you need the system under load as well as everything connected and on.
You will have 0 volts on the negative side of the coil when the points are closed(ignition on/engine off). That 0 volts will go from the negative side of the coil through the points all the way to ground.

When the points are open you will have battery voltage all the way from the battery to the coil? side of the points' contacts. The other side of the points' contacts will have 0 volts.

You should hook your meter up to the coil and fire the bike up. You need to look at the circuit when it fails.
meter on DC V
black probe on negative battery post
red meter probe on negative coil terminal
the voltage will bounce between 12v and 0v.
but i want to know what the meter says when the engine dies.
Also, note the position of the points open or closed


I can't get that as it won't start or run at all, gonna try and spend some time going over the wiring some more tomorrow to find an issue!

Please Log in or Create an account to join the conversation.

More
12 Aug 2020 12:25 - 12 Aug 2020 22:13 #832733 by F64
Replied by F64 on topic Won't start
well, going back to the first measurements you took it appears the primary side of your ignition is working.

The secondary could be at fault- spark plugs, plug wires, spark plug caps, secondary coil windings.

Which plugs do you have?

Did you buy Kawasaki points and condenser?

Which coil did you buy?

Measure the resistance with one probe in one spark plug cap and the other probe in the other spark plug cap.
Note resistance

Measure the resistance of your spark plugs from the terminal nut to the center electrode.
Note resistance


photo:summit racing

81-KZ440-D2.
Louis Dudzik's GM HEI ignitor conversion installed 2015 s3.amazonaws.com/gpzweb/Ignition/GPZgmHEImod.html
Motogadget m-unit blue installed 2017.
LIC, NY
Attachments:
Last edit: 12 Aug 2020 22:13 by F64.

Please Log in or Create an account to join the conversation.

Powered by Kunena Forum

If you like KZR Please consider making a donation. Thank you.

KZRider is free, but not without cost.

Please consider chipping in a few bucks to help cover the cost of running the KZR servers.